Split system playing up? Here's what each symptom actually means.
Water on the floor, a musty smell every time it starts, weak heat in the middle of winter, or a noise that wasn't there last year. Most split system faults are one of five things, and a genuinely large share are a filter or a blocked drain rather than a broken machine. Symptom by symptom: what causes it, what you can fix yourself in ten minutes for nothing, what needs a licensed technician — and the one sign that means switch it off at the switchboard right now.
Reviewed by the Mission Green Energy Team · Updated August 2026
Most split system faults
are one of five things.
Find your symptom, and know before you call whether it's a ten-minute job you can do yourself or a real repair.
Split systems fail in fairly predictable ways, and a surprising share of “my aircon is broken” calls turn out to be a filter, a drain or a setting. This guide is ordered by what you can actually see or hear, with the honest split between fix it yourself, book a technician and stop and get it checked properly.
One rule before anything else: if you can smell burning, see scorching around the indoor unit, or the circuit breaker trips repeatedly, turn it off at the switchboard and call a licensed electrician or technician. Repeated breaker trips are a fault telling you something, not a nuisance to be reset around.
It's leaking water
inside the house.
The most common split system callout there is — and usually the least serious.
Your indoor unit produces water whenever it cools. Warm room air hits the cold evaporator coil, moisture condenses out, collects in a drip tray, and leaves through a small condensate drain line to the outside. Water appearing inside means that path has failed somewhere. In order of likelihood:
- A blocked condensate drain. This is far and away the most common cause — industry service data puts blocked drains at roughly 85% of internal leak callouts. Dust, algae, mould and biofilm build up in the line over years and eventually it stops flowing, so the tray overflows into your room. Australian pests contribute too: geckos, wasps and ants nest in the small dark pipe.
- Clogged filters. Restricted airflow makes the coil run colder than designed until it ices over. When the unit stops and the ice melts, far more water arrives than the tray can hold and it overflows. If your leak comes with weak airflow, suspect this first — and it's free to fix.
- Low refrigerant. An undercharged system also causes the coil to freeze and then flood on melt. This one is a genuine fault: it means the system has a leak, and the fix is to find and repair it, not to top it up — see why a healthy system never needs regassing.
- A poor install. An indoor unit mounted slightly out of level, or a drain line that runs uphill or sags into a water trap, will never drain reliably. If the unit has leaked since it was installed, this is likely and it is the installer's problem to fix.
What you can do: turn the unit off, clean the filters, and check that the outdoor end of the drain pipe is actually dripping when the unit runs in cooling. If it's dry while water is appearing indoors, the line is blocked. A gentle flush or a wet/dry vacuum applied at the outdoor end clears many blockages. If that doesn't do it, or the pipe is inaccessible, book a service — a full indoor clean is usually what's needed.
It smells musty,
sour or like feet.
Almost always biological, almost always the indoor coil — and worth acting on.
That distinctive sour, damp-sock smell when the unit first kicks on has a name in the trade — dirty sock syndrome — and a straightforward cause. The indoor coil and blower wheel stay damp during cooling, dust settles on them, and mould and bacteria grow in the resulting biofilm. Every time the fan starts, it blows air across that growth and into your room.
Filter cleaning helps but often isn't enough on its own, because the growth is on the coil fins and inside the blower wheel, behind the filters. That's what a proper professional clean addresses, and it's one of the genuinely worthwhile services to pay for — unlike a regas.
Two other smells worth distinguishing. A sharp chemical or sweetish smell can indicate a refrigerant leak — ventilate the room and get it checked. A burning or hot-electrical smell means turn it off at the switchboard now and call a technician; that is not something to run and monitor.
Prevention is simple and free: run the unit in fan mode for 10–20 minutes after a long cooling session, or use the dry/self-clean function if your unit has one. Drying the coil before shutdown is what stops the growth taking hold in the first place.
It's not heating
properly in winter.
Four causes, and one of them isn't a fault at all.
It's running a defrost cycle
In cold, damp weather frost forms on the outdoor coil and the unit briefly reverses to melt it. During defrost it stops delivering heat, the outdoor unit may steam, and you may hear a clunk as the valve switches. This is normal, lasts a few minutes, and is more frequent in humid cold. Not a fault.
Filters and outdoor airflow
The same airflow problems that hurt cooling hurt heating. Clean the indoor filters, and check the outdoor unit isn't blocked by a hedge, leaf litter, a fence built too close or something stored against it. In heating, the outdoor coil is collecting heat — it needs air moving through it.
Wrong unit for your climate
If it heats poorly only on the coldest nights, it may simply be a unit without cold-climate capability. Efficiency and output both fall as ambient temperature drops; a cold-climate H2-rated unit holds up far better. That's a specification problem, not something a technician can repair.
The fourth cause is a genuine fault: a failed reversing valve, a refrigerant leak, or a failing outdoor fan or compressor. The tell is that the unit cools fine but won't heat at all, or that heating has degraded steadily rather than only on cold nights. That needs a technician — and if the diagnosis is a refrigerant leak, insist on the leak being found and repaired rather than the system simply being topped up.
One thing worth ruling out before you call anyone: check the remote is actually in heat mode and not auto, and that the setpoint is above the current room temperature. It sounds obvious. It is also a meaningful share of winter callouts.
It's making a noise,
or icing up.
What each sound usually means, and which ones can wait.
- Clicking at start and stop — usually normal relay and valve operation.
- A clunk in cold weather — usually the reversing valve switching in or out of defrost. Normal.
- Gurgling or bubbling — refrigerant moving, or water in the drain line. Usually normal; persistent bubbling with poor performance can indicate a low charge.
- Rattling or vibration — loose cover, mounting bracket or debris in the outdoor fan. Worth checking; cheap to fix.
- Grinding or screeching — a failing fan motor bearing or compressor. Turn it off and book a technician; running it will not improve matters.
- Loud buzzing with the breaker tripping — electrical fault. Switch off at the switchboard and call a licensed electrician.
Ice on the indoor coil in cooling almost always traces back to restricted airflow (dirty filters, blocked return) or low refrigerant. Turn the unit off and let it thaw fully before running it again — running an iced system risks liquid refrigerant returning to the compressor, which is an expensive way to find out. Clean the filters, run again, and if it re-ices, it needs a technician. Frost on the outdoor unit in winter, by contrast, is expected and is what the defrost cycle exists to handle.
So — what should you
actually do first?
In order, cheapest first.
1. Clean the filters. Ten minutes, free, and it resolves or improves a genuinely large share of complaints — weak airflow, icing, overflow leaks, mild smells, poor heating.
2. Clear the outdoor unit. Cut back vegetation, sweep out leaf litter, make sure it has breathing room on all sides.
3. Check the drain runs. With the unit cooling, confirm water is dripping from the outdoor end of the condensate line.
4. Check the obvious settings. Right mode, sensible setpoint, and no window or door quietly undoing the work.
5. Then book a technician — and describe the symptom precisely, because “it's leaking water from the left side of the indoor unit only when cooling” gets a better outcome than “it's not working”. If they diagnose low refrigerant, ask how they intend to find the leak before you agree to any gas.
And if the unit is 12–15 years old and the repair is substantial, price a replacement alongside it. A modern inverter unit is far cheaper to run than a fixed-speed unit of that vintage, and the running-cost saving often changes the answer — our guide on reverse cycle running costs has the numbers.
Split system air conditioner problems:
your questions, answered.
In the great majority of cases, a blocked condensate drain. Your indoor unit condenses moisture out of the room air whenever it cools, and that water collects in a drip tray and drains outside through a small pipe. Over years, dust, algae, mould and sometimes insects or geckos block that line, so the tray overflows into the room — industry service data attributes roughly 85% of internal leak callouts to blocked drains. The next most common cause is clogged filters: restricted airflow makes the coil ice over, and when the ice melts the tray floods. Low refrigerant can cause the same icing, and a unit mounted out of level or a sagging drain line will leak from day one. Start by turning the unit off, cleaning the filters, and checking whether water actually drips from the outdoor end of the drain pipe while it runs. If the pipe is dry while water appears indoors, the line is blocked.
Almost always mould and bacteria growing on the indoor coil and blower wheel. During cooling those components stay damp, dust settles on them, and a biofilm develops that the fan then blows into your room — the sour, damp-sock smell often called dirty sock syndrome. Cleaning the filters helps but frequently is not enough, because the growth sits on the coil fins and inside the blower wheel behind the filters, which is what a professional deep clean addresses. To prevent it recurring, run the unit in fan mode for ten to twenty minutes after long cooling sessions, or use the dry or self-clean function if fitted, so the coil dries before shutdown. Two smells need different treatment: a sharp chemical or sweetish smell can indicate a refrigerant leak and should be checked, and any burning or hot electrical smell means switching the unit off at the switchboard and calling a technician immediately.
Four possibilities, and the first is not a fault. In cold, damp weather the unit periodically runs a defrost cycle, briefly reversing to melt frost off the outdoor coil; during those few minutes it stops delivering heat and the outdoor unit may steam. That is normal. Second, check airflow: dirty indoor filters and an outdoor unit blocked by vegetation, leaf litter or a fence built too close will both cripple heating, because in heating mode the outdoor coil needs airflow to collect heat. Third, the unit may simply lack cold-climate capability — output and efficiency fall as ambient temperature drops, and a cold-climate H2-rated unit holds up far better on genuinely cold nights. Fourth, a real fault such as a failed reversing valve, a refrigerant leak or a failing fan or compressor, which is likely if the unit cools normally but will not heat at all. Before calling anyone, confirm the remote is in heat mode rather than auto and the setpoint is above room temperature.
Ice on the indoor coil during cooling is nearly always caused by restricted airflow or low refrigerant. Dirty filters, a blocked return air path or a failing indoor fan all reduce airflow across the coil, so it runs colder than designed until moisture on it freezes. Low refrigerant produces the same result by dropping the pressure and therefore the coil temperature. Turn the unit off and let it thaw completely before running it again, because operating an iced system risks liquid refrigerant returning to the compressor, which is an expensive failure. Clean the filters, run it again, and if it re-ices then it needs a technician — and if the diagnosis is low refrigerant, insist the leak is found and repaired rather than simply topped up. Frost on the outdoor unit in winter is a different matter entirely: that is expected in cold damp conditions and is exactly what the defrost cycle exists to clear.
Clicking as the unit starts and stops is normal relay and valve operation. A clunk in cold weather is usually the reversing valve switching in or out of a defrost cycle, also normal. Gurgling or bubbling is generally refrigerant moving through the circuit or water in the condensate line, though persistent bubbling combined with poor performance can point to a low charge. Rattling or vibration usually means a loose cover, a loose mounting bracket, or debris caught in the outdoor fan, all cheap to check and fix. The noises that mean stop are grinding or screeching, which suggests a failing fan bearing or compressor, and loud buzzing accompanied by the circuit breaker tripping, which is an electrical fault. In those two cases switch the unit off at the switchboard and call a licensed technician or electrician rather than continuing to run it, because repeated breaker trips are the system reporting a fault rather than a nuisance to reset around.
You can safely clean the indoor filters, which is the single highest-value maintenance task and resolves a large share of complaints. You can clear vegetation and leaf litter from around the outdoor unit and gently hose its fins, avoiding a pressure washer, which bends fins and makes them worse. You can check that the condensate drain is discharging outside and attempt a gentle flush of an accessible drain line. You can check settings, modes and setpoints. Everything else belongs to a technician: anything involving refrigerant is licensed work in Australia requiring an ARCtick refrigerant handling licence, and anything involving the electrical supply, a tripping breaker, burning smells or scorching should be switched off at the switchboard and left to a licensed electrician. Deep cleaning of the indoor coil and blower wheel is also worth paying for rather than attempting, since it involves dismantling parts of the indoor unit and using chemicals near live electrical components.
Where these figures come from.
Figures on this page are drawn from primary sources and were current as at August 2026. Programs, prices and standards change — confirm at the source before relying on a number.
- Australian Refrigeration Council — ARCtick licence requirements and technician register (arctick.org)
- energy.gov.au — Heating and cooling for Australian households
- Energy Rating — Air conditioners and the Zoned Energy Rating Label (energyrating.gov.au)
- ACCC — Consumer guarantees on goods and repairs (accc.gov.au)
- ACT Everyday Climate Choices — cold-climate reverse cycle performance (climatechoices.act.gov.au)