Air Conditioning Troubleshooting Guide

Split system playing up? Here's what each symptom actually means.

Water on the floor, a musty smell every time it starts, weak heat in the middle of winter, or a noise that wasn't there last year. Most split system faults are one of five things, and a genuinely large share are a filter or a blocked drain rather than a broken machine. Symptom by symptom: what causes it, what you can fix yourself in ten minutes for nothing, what needs a licensed technician — and the one sign that means switch it off at the switchboard right now.

Reviewed by the Mission Green Energy Team · Updated August 2026

SAA-Accredited InstallersSolar Accreditation Australia
10 Year WarrantyBacked by Mission Green
$0 Upfront Finance (subject to approval)Brighte, Plenti & 28Watts approved
7 States CoveredAustralia-wide service

Most split system faults
are one of five things.

Find your symptom, and know before you call whether it's a ten-minute job you can do yourself or a real repair.

It's leaking water
inside the house.

The most common split system callout there is — and usually the least serious.

It smells musty,
sour or like feet.

Almost always biological, almost always the indoor coil — and worth acting on.

If anyone in the house has asthma or allergies, don’t let a musty split system run for months untreated — you are circulating mould spores through the room every time it starts. This is one of the few cases where we’d say get the professional clean sooner rather than waiting for the annual service.

It's not heating
properly in winter.

Four causes, and one of them isn't a fault at all.

Not a fault

It's running a defrost cycle

In cold, damp weather frost forms on the outdoor coil and the unit briefly reverses to melt it. During defrost it stops delivering heat, the outdoor unit may steam, and you may hear a clunk as the valve switches. This is normal, lasts a few minutes, and is more frequent in humid cold. Not a fault.

Check first

Filters and outdoor airflow

The same airflow problems that hurt cooling hurt heating. Clean the indoor filters, and check the outdoor unit isn't blocked by a hedge, leaf litter, a fence built too close or something stored against it. In heating, the outdoor coil is collecting heat — it needs air moving through it.

Real limit

Wrong unit for your climate

If it heats poorly only on the coldest nights, it may simply be a unit without cold-climate capability. Efficiency and output both fall as ambient temperature drops; a cold-climate H2-rated unit holds up far better. That's a specification problem, not something a technician can repair.

It's making a noise,
or icing up.

What each sound usually means, and which ones can wait.

So — what should you
actually do first?

In order, cheapest first.

Split system air conditioner problems:
your questions, answered.

In the great majority of cases, a blocked condensate drain. Your indoor unit condenses moisture out of the room air whenever it cools, and that water collects in a drip tray and drains outside through a small pipe. Over years, dust, algae, mould and sometimes insects or geckos block that line, so the tray overflows into the room — industry service data attributes roughly 85% of internal leak callouts to blocked drains. The next most common cause is clogged filters: restricted airflow makes the coil ice over, and when the ice melts the tray floods. Low refrigerant can cause the same icing, and a unit mounted out of level or a sagging drain line will leak from day one. Start by turning the unit off, cleaning the filters, and checking whether water actually drips from the outdoor end of the drain pipe while it runs. If the pipe is dry while water appears indoors, the line is blocked.

Almost always mould and bacteria growing on the indoor coil and blower wheel. During cooling those components stay damp, dust settles on them, and a biofilm develops that the fan then blows into your room — the sour, damp-sock smell often called dirty sock syndrome. Cleaning the filters helps but frequently is not enough, because the growth sits on the coil fins and inside the blower wheel behind the filters, which is what a professional deep clean addresses. To prevent it recurring, run the unit in fan mode for ten to twenty minutes after long cooling sessions, or use the dry or self-clean function if fitted, so the coil dries before shutdown. Two smells need different treatment: a sharp chemical or sweetish smell can indicate a refrigerant leak and should be checked, and any burning or hot electrical smell means switching the unit off at the switchboard and calling a technician immediately.

Four possibilities, and the first is not a fault. In cold, damp weather the unit periodically runs a defrost cycle, briefly reversing to melt frost off the outdoor coil; during those few minutes it stops delivering heat and the outdoor unit may steam. That is normal. Second, check airflow: dirty indoor filters and an outdoor unit blocked by vegetation, leaf litter or a fence built too close will both cripple heating, because in heating mode the outdoor coil needs airflow to collect heat. Third, the unit may simply lack cold-climate capability — output and efficiency fall as ambient temperature drops, and a cold-climate H2-rated unit holds up far better on genuinely cold nights. Fourth, a real fault such as a failed reversing valve, a refrigerant leak or a failing fan or compressor, which is likely if the unit cools normally but will not heat at all. Before calling anyone, confirm the remote is in heat mode rather than auto and the setpoint is above room temperature.

Ice on the indoor coil during cooling is nearly always caused by restricted airflow or low refrigerant. Dirty filters, a blocked return air path or a failing indoor fan all reduce airflow across the coil, so it runs colder than designed until moisture on it freezes. Low refrigerant produces the same result by dropping the pressure and therefore the coil temperature. Turn the unit off and let it thaw completely before running it again, because operating an iced system risks liquid refrigerant returning to the compressor, which is an expensive failure. Clean the filters, run it again, and if it re-ices then it needs a technician — and if the diagnosis is low refrigerant, insist the leak is found and repaired rather than simply topped up. Frost on the outdoor unit in winter is a different matter entirely: that is expected in cold damp conditions and is exactly what the defrost cycle exists to clear.

Clicking as the unit starts and stops is normal relay and valve operation. A clunk in cold weather is usually the reversing valve switching in or out of a defrost cycle, also normal. Gurgling or bubbling is generally refrigerant moving through the circuit or water in the condensate line, though persistent bubbling combined with poor performance can point to a low charge. Rattling or vibration usually means a loose cover, a loose mounting bracket, or debris caught in the outdoor fan, all cheap to check and fix. The noises that mean stop are grinding or screeching, which suggests a failing fan bearing or compressor, and loud buzzing accompanied by the circuit breaker tripping, which is an electrical fault. In those two cases switch the unit off at the switchboard and call a licensed technician or electrician rather than continuing to run it, because repeated breaker trips are the system reporting a fault rather than a nuisance to reset around.

You can safely clean the indoor filters, which is the single highest-value maintenance task and resolves a large share of complaints. You can clear vegetation and leaf litter from around the outdoor unit and gently hose its fins, avoiding a pressure washer, which bends fins and makes them worse. You can check that the condensate drain is discharging outside and attempt a gentle flush of an accessible drain line. You can check settings, modes and setpoints. Everything else belongs to a technician: anything involving refrigerant is licensed work in Australia requiring an ARCtick refrigerant handling licence, and anything involving the electrical supply, a tripping breaker, burning smells or scorching should be switched off at the switchboard and left to a licensed electrician. Deep cleaning of the indoor coil and blower wheel is also worth paying for rather than attempting, since it involves dismantling parts of the indoor unit and using chemicals near live electrical components.

Where these figures come from.

Figures on this page are drawn from primary sources and were current as at August 2026. Programs, prices and standards change — confirm at the source before relying on a number.

Keep reading

Related honest guides.

Does a split system need regassing?

Almost certainly not — and knowing why protects you from the most common upsell.

Read the guide →

Is a reverse cycle air conditioner a heat pump?

Yes — and it explains the defrost cycle, the cold-weather limits and your bill.

Read the guide →

Reverse cycle vs gas heating: what's really cheaper?

If you're deciding between repair and replacement, start with the running cost.

Read the guide →

Old unit, big repair quote, and not sure whether to fix or replace?

Book a free energy assessment. We'll weigh the repair against a replacement's running cost on your actual tariff and solar — and if repairing is the better call, we'll say so.

Book Free Assessment →