GoodWe inverter error codes: Utility Loss, Isolation Failure and the rest

As at November 2026, GoodWe shows faults two ways: a name such as Utility Loss or Isolation Failure on DNS, XS, MS and ET models, or a numbered code from F01 on the EH hybrid and ESA. Most red lights after a storm or on a hot afternoon are grid or temperature faults that clear themselves. Here is how to tell.

Written by Juan Flinn, Content Editor · Reviewed by the Mission Green Energy Team · Updated 9 November 2026

Which kind of GoodWe error
are you looking at?

A word or an F-number. Both point at the same handful of causes.

Usually clears itself

Utility Loss · Vac · F01–F11

Grid outage, voltage or frequency. Wait, then watch whether it repeats.

Often clears when dry

Isolation · GFCI · F12–F18

Leakage to earth. One damp morning is weather; every damp morning is a fault.

Call, don’t reset

Arc · Ground · F19 · F42

Arc faults and earthing faults. Leave the switches and call your installer.

Which GoodWe error
is on your screen?

Names from the DNS (V1.3, September 2026), XS (V1.7, August 2026), MS (V1.2, November 2024) and ET (V2.0, September 2026) manuals; codes from the EH (V2.3, May 2026) and ESA (V1.0, January 2026) manuals. The plain-English wording is ours.

Message (DNS, XS, MS, ET)Code (EH, ESA)What it meansWhat you can safely do
Utility LossF01 Grid Power OutageNo grid: a blackout, or the inverter’s AC cable or breaker is off.Check whether the house and street have power. The ET and EH manuals say it clears once the grid is back. If the house has power, call your installer.
Vac Failure; Grid Overvoltage / Undervoltage (ET)F02–F05Grid voltage outside the allowed range, including a 10-minute average that runs too high.Wait. The DNS and XS manuals say it restarts within 5 minutes once the grid is normal. If it repeats most afternoons, tell your installer.
Fac Failure; Grid Over/Underfrequency (ET)F06–F08Grid frequency outside the allowed range or changing too fast.Wait. If it repeats, call your installer.
Anti-islanding (ET)F09 Anti-islanding ProtectionThe grid dropped out but something kept voltage on the line, so the inverter stopped as the safety rules require.Wait for the grid. If it repeats, call your installer.
Isolation Failure; Low Insulation Res. (ET)F18 Low Insulation ResistanceInsulation between the solar wiring and earth is too low. On Australian models a buzzer sounds.Don’t touch anything. If it cleared once after rain, note it. If it repeats, call an electrician.
Ground I Failure; Abnormal GFCI (ET)F12–F15 GFCI ProtectionToo much current leaking to earth while running.The EH manual says an occasional one clears by itself. Frequent or lasting: call an electrician.
Abnormal Ground (ET)F19 Grounding AbnormalThe inverter’s earth wire is not connected properly.Don’t touch anything. Call your installer.
AFCI-Fault; DC Arc Fault (ET)F42 DC Arcing FailureArcing in the solar wiring: loose terminals or a damaged cable.Don’t reset it. Call your installer.
Over Temperature; Cavity Overtemperature (ET)F35 Cabinet OvertemperatureToo hot inside the inverter: poor ventilation, high ambient temperature or a fan fault.Wait for it to cool. Make sure nothing is stacked against it. If it repeats, call your installer.
PV Over Voltage; PV Input Overvoltage (ET)F37 PV Input OvervoltageThe panels’ voltage is above the inverter’s maximum: too many panels in a string.Call your installer. It is a design problem, not a passing fault.
Relay-Check Failure; Relay Check abnormal, Internal Comm Loss (ET)F21, F32An internal check failed.The manuals’ step is AC and DC off, back on after 5 minutes (see the restart below). If it returns, call.
Back-up output overload (ET light)F55 Back-up Port OverloadToo much running on the backup circuits during an outage.Switch off some big loads on backup.
—F140 Meter Comm Loss; F143, F144 CT faultsThe inverter has lost its meter, or the current sensor is missing or reversed.Call your installer. Usage and export figures will be wrong until it’s fixed.
COM light, 1 blue blink (ET)—The ET manual: BMS communication has failed, so the inverter has lost its link to the battery.Call your installer.
—F126 Abnormal Battery ConnectionThe inverter reads the battery connection as abnormal.Call your installer.
—F127 BAT OvertemperatureOver-temperature on the battery side; the manual lists poor ventilation, heat or a fan fault.Check nothing is heating it or blocking airflow. If it persists, call your installer.

Why does a GoodWe show Utility Loss
after a storm or on a sunny afternoon?

Because the grid moved, not because the inverter broke.

What does Isolation Failure mean,
and why is it beeping?

The one GoodWe message that comes with a sound.

⚠
Never open the inverter or touch the solar wiring. Some GoodWe steps for Ground I Failure and Isolation Failure involve unplugging DC connectors. Those are written for electricians. The panels and their cables stay live in daylight even with every switch off. If there is smoke, a burning smell, scorching or a buzzing switch, switch off the inverter’s AC supply at your switchboard only if it is safe to reach, keep away, and call a licensed electrician.

Why does a GoodWe show Over Temperature
on hot afternoons?

Heat, airflow, and the timing that gives it away.

What do GoodWe battery errors look like
on ET, EH, Lynx and ESA?

Lights on the battery, messages in the app, and one thing that isn’t a fault.

Where do GoodWe’s own
documents conflict?

We read seven current GoodWe manuals for this page. They don’t all agree.

TopicWhat the manuals sayWhat it means for you
Names vs codesDNS, XS, MS and ET say Utility Loss; EH and ESA say F01 Grid Power Outage.Same event. Search for both.
ET table numbersThe ET manual numbers its fault rows 1 to 36, but they don’t match the F-codes: row 3 is Grid Rapid Overvoltage, while F03 is Grid Undervoltage.An ET row number is not an F-code. Use the name.
Insulation limitXS: 150 kΩ. DNS and MS: 100 kΩ. EH and ESA: 80 kΩ. ET: 50 kΩ.Only an electrician can measure it, against your model’s figure.
Isolation buzzerDNS, XS, MS, EH and ESA: 1 minute, then every 30 minutes. ET: 30 seconds, then every 30 minutes.Either way, a beep means an insulation fault.
Fac FailureThe DNS and XS manuals give this frequency fault the same “not connected to the grid” steps as Utility Loss.Treat it as a grid fault: wait, then call if it repeats.
Power-on orderDNS, ET and EH switch the AC on first. The ESA powers the battery on first and the grid breaker last.Follow your own model’s order, below.
Battery buttonLynx Home F G2: hold 15 seconds to power off, 5 to 10 seconds for a black start. ESA: hold 5 seconds to power off.Never hold a battery button by guesswork.

How do I safely restart
a GoodWe inverter?

Once, in your model’s order, and only for the right errors.

ModelSwitching offSwitching back on (after 5 minutes)
DNS, XS, MS (string)AC switch off, then the inverter’s DC switch offAC switch on, then any separate DC isolator, then the inverter’s DC switch
ET hybridAC switch off, then the battery switch, then the inverter’s DC switchAC switch on, then the battery switch, then the DC switches
EH hybridGrid AC breaker, backup AC breaker, battery breaker, then the DC switchThe same order: grid AC, backup AC, battery, then DC
ESABackup breaker, grid breaker, then the battery (button, then switch), then DCBattery first, then DC, then the grid breaker, then the backup breaker

Is a GoodWe fault
covered by warranty?

GoodWe’s Australian terms, revision 5.9, 17 September 2026.

When should you stop
and call an electrician?

Any one of these is enough.

GoodWe error codes:
your questions, answered.

Utility Loss means the inverter can't see the grid, usually because of a blackout, or because its AC cable or breaker is off. The newer EH (V2.3, May 2026) and ESA (V1.0, January 2026) manuals call the same fault F01 Grid Power Outage. GoodWe's ET and EH manuals say the alarm clears by itself once grid power returns. If your house has power and the message stays, call your installer rather than resetting a tripped breaker.

Isolation Failure means the inverter has measured too little insulation between the solar wiring and earth, often from moisture in a connector or a damaged cable. The EH and ESA manuals (2026 editions) call it F18 Low Insulation Resistance. One episode on a damp morning that clears is worth noting; if it happens on dry days or every time it rains, an electrician needs to test the wiring. Never touch the DC cables yourself.

On GoodWe inverters sold in Australia and New Zealand, the buzzer is the insulation fault alarm. The DNS manual (V1.3, September 2026) says it sounds for one minute, then every 30 minutes until the fault clears; the ET manual (V2.0, September 2026) says 30 seconds. Either way it means Isolation Failure or low insulation resistance. Don't touch the inverter, its cables or isolators; check the app for the message and call your installer.

F codes are how GoodWe's newer manuals number faults. In the EH manual (V2.3, May 2026) and ESA manual (V1.0, January 2026), F01 is Grid Power Outage, F02 to F11 are grid voltage and frequency faults, F12 to F15 are earth-leakage faults, F18 is low insulation, F35 is cabinet over-temperature and F42 is a DC arc fault. Older DNS, XS, MS and ET manuals use names such as Utility Loss for the same faults.

Once, in your model's order, and not for an arc fault, Abnormal Ground or a repeating Isolation Failure. On DNS, XS and MS string inverters, GoodWe's 2024–2026 manuals say switch the AC off, then the inverter's DC switch; wait at least 5 minutes; then AC on first and DC on last. Hybrids add the battery breaker, and the ESA powers the battery on first. If the error returns, stop and call your installer.

Often it isn't a fault. GoodWe's ET manual (V2.0, September 2026) says the battery won't discharge continuously unless the home is using more than 150 W, won't go below its set depth of discharge, and won't discharge during a charge period set in the app. Check those settings with your installer first. A steady red light on a Lynx Home F battery, by contrast, is a fault.

Under GoodWe's Australia and New Zealand terms (Rev 5.9, 17 September 2026), the DNS, XS, MS, ET 5–10 kW and EH have a 5-year standard warranty, and newer ranges such as the ET G2 and ESA have 10 years. Older ranges can reach 10 years if they meet GoodWe's registration conditions. Claims go through your installer first and should be made within one month of the failure.

Where these
figures come from.

Every message, code and step above comes from GoodWe’s own documents, downloaded from goodwe.com.au and read 9 November 2026. The plain-English summaries are ours. This is general information: your installer and your model’s manual come first.

Keep reading

Related honest guides.

Inverter red light?

Every brand’s light table, the one safe reset, and when to call.

Read the guide →

Is my solar working?

Four checks from the driveway, and the failures that never trigger a light.

Read the guide →

Solar stopped exporting?

Inverter faults, meters, export limits and grid voltage, in order.

Read the guide →

GoodWe Lynx vs ESA

Two very different GoodWe battery systems, and who each suits.

Read the guide →

Battery acting oddly?

Six normal reasons a battery charges from the grid, and the signs of a real fault.

Read the guide →

Repair or replace?

How long inverters last, the signs, and the 8-year repair rule.

Read the guide →

Same GoodWe error every week?

Send us the message and when it happens. We’ll tell you honestly whether it’s the grid, the weather or the hardware, and whether it needs anyone at all.