GoodWe inverter error codes: Utility Loss, Isolation Failure and the rest
As at November 2026, GoodWe shows faults two ways: a name such as Utility Loss or Isolation Failure on DNS, XS, MS and ET models, or a numbered code from F01 on the EH hybrid and ESA. Most red lights after a storm or on a hot afternoon are grid or temperature faults that clear themselves. Here is how to tell.
Written by Juan Flinn, Content Editor · Reviewed by the Mission Green Energy Team · Updated 9 November 2026
Which kind of GoodWe error
are you looking at?
A word or an F-number. Both point at the same handful of causes.
The DNS, XS and MS string inverters and the ET hybrid show the fault as words on the screen or in the SEMS app. The DNS manual splits them into System Failure (something outside the box: grid, panels, insulation, heat) and Inverter Failure (something inside it, such as Relay-Check Failure or EEPROM R/W Failure).
The EH hybrid manual (V2.3, May 2026) and the manual for the ESA all-in-one system (V1.0, January 2026) number every fault: F01 is Grid Power Outage, F02 to F11 are other grid faults, F12 to F15 are earth-leakage faults, F18 is low insulation, and the list runs past F150. The same event can have two labels: what an older inverter calls Utility Loss, the newer manuals call F01.
What each GoodWe light means is on our inverter red light guide. This page is about the messages and codes. Other brands: Sungrow fault codes and Fronius state codes.
Utility Loss · Vac · F01–F11
Grid outage, voltage or frequency. Wait, then watch whether it repeats.
Isolation · GFCI · F12–F18
Leakage to earth. One damp morning is weather; every damp morning is a fault.
Arc · Ground · F19 · F42
Arc faults and earthing faults. Leave the switches and call your installer.
Which GoodWe error
is on your screen?
Names from the DNS (V1.3, September 2026), XS (V1.7, August 2026), MS (V1.2, November 2024) and ET (V2.0, September 2026) manuals; codes from the EH (V2.3, May 2026) and ESA (V1.0, January 2026) manuals. The plain-English wording is ours.
| Message (DNS, XS, MS, ET) | Code (EH, ESA) | What it means | What you can safely do |
|---|---|---|---|
| Utility Loss | F01 Grid Power Outage | No grid: a blackout, or the inverter’s AC cable or breaker is off. | Check whether the house and street have power. The ET and EH manuals say it clears once the grid is back. If the house has power, call your installer. |
| Vac Failure; Grid Overvoltage / Undervoltage (ET) | F02–F05 | Grid voltage outside the allowed range, including a 10-minute average that runs too high. | Wait. The DNS and XS manuals say it restarts within 5 minutes once the grid is normal. If it repeats most afternoons, tell your installer. |
| Fac Failure; Grid Over/Underfrequency (ET) | F06–F08 | Grid frequency outside the allowed range or changing too fast. | Wait. If it repeats, call your installer. |
| Anti-islanding (ET) | F09 Anti-islanding Protection | The grid dropped out but something kept voltage on the line, so the inverter stopped as the safety rules require. | Wait for the grid. If it repeats, call your installer. |
| Isolation Failure; Low Insulation Res. (ET) | F18 Low Insulation Resistance | Insulation between the solar wiring and earth is too low. On Australian models a buzzer sounds. | Don’t touch anything. If it cleared once after rain, note it. If it repeats, call an electrician. |
| Ground I Failure; Abnormal GFCI (ET) | F12–F15 GFCI Protection | Too much current leaking to earth while running. | The EH manual says an occasional one clears by itself. Frequent or lasting: call an electrician. |
| Abnormal Ground (ET) | F19 Grounding Abnormal | The inverter’s earth wire is not connected properly. | Don’t touch anything. Call your installer. |
| AFCI-Fault; DC Arc Fault (ET) | F42 DC Arcing Failure | Arcing in the solar wiring: loose terminals or a damaged cable. | Don’t reset it. Call your installer. |
| Over Temperature; Cavity Overtemperature (ET) | F35 Cabinet Overtemperature | Too hot inside the inverter: poor ventilation, high ambient temperature or a fan fault. | Wait for it to cool. Make sure nothing is stacked against it. If it repeats, call your installer. |
| PV Over Voltage; PV Input Overvoltage (ET) | F37 PV Input Overvoltage | The panels’ voltage is above the inverter’s maximum: too many panels in a string. | Call your installer. It is a design problem, not a passing fault. |
| Relay-Check Failure; Relay Check abnormal, Internal Comm Loss (ET) | F21, F32 | An internal check failed. | The manuals’ step is AC and DC off, back on after 5 minutes (see the restart below). If it returns, call. |
| Back-up output overload (ET light) | F55 Back-up Port Overload | Too much running on the backup circuits during an outage. | Switch off some big loads on backup. |
| — | F140 Meter Comm Loss; F143, F144 CT faults | The inverter has lost its meter, or the current sensor is missing or reversed. | Call your installer. Usage and export figures will be wrong until it’s fixed. |
| COM light, 1 blue blink (ET) | — | The ET manual: BMS communication has failed, so the inverter has lost its link to the battery. | Call your installer. |
| — | F126 Abnormal Battery Connection | The inverter reads the battery connection as abnormal. | Call your installer. |
| — | F127 BAT Overtemperature | Over-temperature on the battery side; the manual lists poor ventilation, heat or a fan fault. | Check nothing is heating it or blocking airflow. If it persists, call your installer. |
If your message or code isn’t here, we couldn’t confirm it in a current GoodWe manual for Australian home models. Write it down exactly, photograph the screen, and ask your installer.
Why does a GoodWe show Utility Loss
after a storm or on a sunny afternoon?
Because the grid moved, not because the inverter broke.
After a storm, expect Utility Loss or F01. The inverter must stop exporting when the grid is down, and F09 Anti-islanding is the same protection catching a grid that dropped out while something held voltage on the line. The ET and EH manuals say the Utility Loss alarm clears by itself once grid power is back. If your street has power and the message stays, the inverter’s own AC breaker may have tripped. Don’t keep switching it back on: call your installer.
On a sunny afternoon, expect Vac Failure or F02 to F05. When a street full of solar exports at once, the local voltage climbs; F05 is the inverter’s 10-minute average running above the limit. The DNS and XS manuals say the inverter restarts within 5 minutes once the grid is normal.
If it happens most afternoons, GoodWe’s steps are to check the grid voltage, contact the network if it is out of range, and change the protection settings only with the network’s consent. That is installer work. Our guide to solar that has stopped exporting explains the voltage problem.
What does Isolation Failure mean,
and why is it beeping?
The one GoodWe message that comes with a sound.
Isolation Failure (F18 on EH and ESA) means the inverter measured too little insulation between the solar wiring and earth. The EH and ESA manuals name a PV string shorted to earth or wiring in a long-term humid environment as causes. GoodWe’s Australian and New Zealand inverters add a buzzer: it sounds for a minute, then again every 30 minutes until the fault clears (the ET manual says 30 seconds).
One episode on a foggy morning that clears by mid-morning is moisture and is worth noting, not panicking about. An Isolation Failure on dry days, or every time it rains, means water is getting into a connector or a cable is damaged. Every manual’s next step is measuring the solar wiring’s resistance to earth, which needs an electrician with test gear.
The ET and EH manuals also describe resetting the insulation protection point in the app when readings are low in wet weather. That is a setting for your installer to decide on after testing, not something to change to stop the beeping.
Why does a GoodWe show Over Temperature
on hot afternoons?
Heat, airflow, and the timing that gives it away.
Over Temperature on string models, Cavity Overtemperature on the ET and F35 on EH and ESA all mean the inside of the inverter is too hot. The ET manual lists the causes as poor ventilation, an ambient temperature above 60 °C, or a fault in the internal fan. Every manual’s fixes are about airflow and the temperature around the unit; the DNS and XS manuals go as far as moving the inverter somewhere cooler.
The part you can do is keep the space around it clear. The DNS and ET maintenance tables ask for the heat sink and air vents to be checked for foreign matter or dust every 6 to 12 months: leave that check, and any cleaning near the inverter, to your installer. Shading or moving an inverter is also installer work. If Over Temperature and Vac Failure both appear on the same hot afternoons, write down which one came first. It tells your installer whether to look at airflow or at grid voltage.
What do GoodWe battery errors look like
on ET, EH, Lynx and ESA?
Lights on the battery, messages in the app, and one thing that isn’t a fault.
On a Lynx Home F G2 battery (manual V1.3, August 2024), the button light blinking red twice a second is an alarm: the battery runs a self-check and then returns to operation or goes into fault. Steady red is a fault; the manual reads the fault from the button and charge lights together, so photograph both. On the ESA, battery faults appear in the app as named warnings, such as a charging temperature that is too high, and the manual’s first step for many is to let the battery rest and see if it clears.
On the EH, F126 is an abnormal battery connection and F127 battery over-temperature. On the ET, a single blue blink on the COM light means the link to the battery management system has failed. All of those are installer calls.
A battery that won’t discharge is often not a fault. The ET manual says the battery won’t discharge continuously unless the home is using more than 150 W, won’t discharge below its set depth of discharge, and won’t discharge during a charge period set in the app. More reasons are in why a battery charges from the grid; the two battery ranges are compared in GoodWe Lynx vs ESA.
Where do GoodWe’s own
documents conflict?
We read seven current GoodWe manuals for this page. They don’t all agree.
| Topic | What the manuals say | What it means for you |
|---|---|---|
| Names vs codes | DNS, XS, MS and ET say Utility Loss; EH and ESA say F01 Grid Power Outage. | Same event. Search for both. |
| ET table numbers | The ET manual numbers its fault rows 1 to 36, but they don’t match the F-codes: row 3 is Grid Rapid Overvoltage, while F03 is Grid Undervoltage. | An ET row number is not an F-code. Use the name. |
| Insulation limit | XS: 150 kΩ. DNS and MS: 100 kΩ. EH and ESA: 80 kΩ. ET: 50 kΩ. | Only an electrician can measure it, against your model’s figure. |
| Isolation buzzer | DNS, XS, MS, EH and ESA: 1 minute, then every 30 minutes. ET: 30 seconds, then every 30 minutes. | Either way, a beep means an insulation fault. |
| Fac Failure | The DNS and XS manuals give this frequency fault the same “not connected to the grid” steps as Utility Loss. | Treat it as a grid fault: wait, then call if it repeats. |
| Power-on order | DNS, ET and EH switch the AC on first. The ESA powers the battery on first and the grid breaker last. | Follow your own model’s order, below. |
| Battery button | Lynx Home F G2: hold 15 seconds to power off, 5 to 10 seconds for a black start. ESA: hold 5 seconds to power off. | Never hold a battery button by guesswork. |
How do I safely restart
a GoodWe inverter?
Once, in your model’s order, and only for the right errors.
Don’t restart for a repeating Isolation Failure, an arc fault (AFCI-Fault, DC Arc Fault, F42), Abnormal Ground (F19), or if there is a smell, smoke, scorching or damage. For internal faults, GoodWe’s step is to switch the AC and DC off and back on 5 minutes later. The label on the inverter says to wait 5 minutes after power-off for the inside to discharge. The order depends on the model:
| Model | Switching off | Switching back on (after 5 minutes) |
|---|---|---|
| DNS, XS, MS (string) | AC switch off, then the inverter’s DC switch off | AC switch on, then any separate DC isolator, then the inverter’s DC switch |
| ET hybrid | AC switch off, then the battery switch, then the inverter’s DC switch | AC switch on, then the battery switch, then the DC switches |
| EH hybrid | Grid AC breaker, backup AC breaker, battery breaker, then the DC switch | The same order: grid AC, backup AC, battery, then DC |
| ESA | Backup breaker, grid breaker, then the battery (button, then switch), then DC | Battery first, then DC, then the grid breaker, then the backup breaker |
If the battery steps involve a button, ask your installer to show you once. If the error comes straight back, stop resetting and call. A dark screen doesn’t mean the wiring is safe to touch.
Is a GoodWe fault
covered by warranty?
GoodWe’s Australian terms, revision 5.9, 17 September 2026.
GoodWe’s standard warranty for Australia and New Zealand is 5 years for the DNS, XS, MS, ET 5–10 kW and EH, and 10 years for newer ranges including the ET G2 and the ESA. Older-range inverters can reach 10 years under GoodWe’s promotion: on-grid models must have been made after 1 July 2020 and registered on the SEMS portal after 1 January 2021; ET 5–10 kW and EH hybrids also need a Lynx Home F battery and registration. The Wi-Fi module and smart meter get 2 years. The clock starts at installation or 12 months after manufacture, whichever is earlier.
Claims start with your installer or the distributor; if that fails, you can escalate to GoodWe directly. Two details catch people out: GoodWe asks for the claim within one month of the failure, and it wants the error message from the screen. That is another reason to photograph it. If your installer has gone, see how to claim when the installer is gone.
When should you stop
and call an electrician?
Any one of these is enough.
- Smoke, a burning smell, scorch marks, melted plastic, or a buzzing switch.
- The isolation buzzer, or Isolation Failure on dry days or every time it rains.
- An arc fault, Abnormal Ground, F19 or F42.
- Utility Loss while the house has power, or the same grid fault most sunny afternoons.
- An internal fault that returns after one restart.
- A steady red light on the battery.
Not sure anything is wrong? Our sixty-second solar check helps. If the faults keep piling up on an older unit, read when an inverter needs replacing. More on the brand is on our GoodWe page.
GoodWe error codes:
your questions, answered.
Utility Loss means the inverter can't see the grid, usually because of a blackout, or because its AC cable or breaker is off. The newer EH (V2.3, May 2026) and ESA (V1.0, January 2026) manuals call the same fault F01 Grid Power Outage. GoodWe's ET and EH manuals say the alarm clears by itself once grid power returns. If your house has power and the message stays, call your installer rather than resetting a tripped breaker.
Isolation Failure means the inverter has measured too little insulation between the solar wiring and earth, often from moisture in a connector or a damaged cable. The EH and ESA manuals (2026 editions) call it F18 Low Insulation Resistance. One episode on a damp morning that clears is worth noting; if it happens on dry days or every time it rains, an electrician needs to test the wiring. Never touch the DC cables yourself.
On GoodWe inverters sold in Australia and New Zealand, the buzzer is the insulation fault alarm. The DNS manual (V1.3, September 2026) says it sounds for one minute, then every 30 minutes until the fault clears; the ET manual (V2.0, September 2026) says 30 seconds. Either way it means Isolation Failure or low insulation resistance. Don't touch the inverter, its cables or isolators; check the app for the message and call your installer.
F codes are how GoodWe's newer manuals number faults. In the EH manual (V2.3, May 2026) and ESA manual (V1.0, January 2026), F01 is Grid Power Outage, F02 to F11 are grid voltage and frequency faults, F12 to F15 are earth-leakage faults, F18 is low insulation, F35 is cabinet over-temperature and F42 is a DC arc fault. Older DNS, XS, MS and ET manuals use names such as Utility Loss for the same faults.
Once, in your model's order, and not for an arc fault, Abnormal Ground or a repeating Isolation Failure. On DNS, XS and MS string inverters, GoodWe's 2024–2026 manuals say switch the AC off, then the inverter's DC switch; wait at least 5 minutes; then AC on first and DC on last. Hybrids add the battery breaker, and the ESA powers the battery on first. If the error returns, stop and call your installer.
Often it isn't a fault. GoodWe's ET manual (V2.0, September 2026) says the battery won't discharge continuously unless the home is using more than 150 W, won't go below its set depth of discharge, and won't discharge during a charge period set in the app. Check those settings with your installer first. A steady red light on a Lynx Home F battery, by contrast, is a fault.
Under GoodWe's Australia and New Zealand terms (Rev 5.9, 17 September 2026), the DNS, XS, MS, ET 5–10 kW and EH have a 5-year standard warranty, and newer ranges such as the ET G2 and ESA have 10 years. Older ranges can reach 10 years if they meet GoodWe's registration conditions. Claims go through your installer first and should be made within one month of the failure.
Where these
figures come from.
Every message, code and step above comes from GoodWe’s own documents, downloaded from goodwe.com.au and read 9 November 2026. The plain-English summaries are ours. This is general information: your installer and your model’s manual come first.
- GoodWe — DNS series user manual, V1.3, 10 September 2026
- GoodWe — XS series user manual, V1.7, August 2026
- GoodWe — MS series user manual, V1.2, 25 November 2024
- GoodWe — ET / ET Plus / BT user manual, V2.0, 20 September 2026
- GoodWe — EH series user manual, V2.3, 22 May 2026 (fault codes F01 onward)
- GoodWe — ESA 5–30 kW user manual (Australia), V1.0, 10 January 2026
- GoodWe — Lynx Home F G2 battery user manual (Australia), V1.3, 6 August 2024
- GoodWe — Limited Warranty for Inverter System (Australia and New Zealand), Rev 5.9, 17 September 2026