Sungrow inverter fault codes: what each one means, and what to do

As at November 2026, Sungrow’s manuals sort the codes into families: 2 to 10 are grid faults, 12 and 39 flag damp or insulation problems, 37 is heat, and the 700s to 900s are battery faults. Most red lights after a storm or on a hot afternoon are grid or temperature faults that clear themselves. Here is how to tell.

Written by Juan Flinn, Content Editor · Reviewed by the Mission Green Energy Team · Updated 9 November 2026

What does a Sungrow code
actually tell you?

Which family it is in, and whether the inverter expects to fix itself.

Usually clears itself

2–17 · 37

Grid voltage, frequency or outage, and heat. Wait, then watch whether it repeats.

Often clears when dry

12 · 39

Leakage current and low insulation resistance. One wet morning is weather; every wet morning is a fault.

Call, don’t reset

88 · 106 · 1600s · 1616

Arc fault, grounding faults and a hardware fault. Leave the switches and call your installer.

Which Sungrow code
is on your screen?

Codes and names from Sungrow’s SG2.0–6.0RS manual (Ver24, June 2025), SH3.0–6.0RS hybrid manual (Ver20, March 2025), SH5.0–10RT manual (Ver24, March 2025) and SBR battery manual (Ver22, February 2025). The wording is our summary, not the manual’s.

CodeManual’s nameWhat it meansWhat you can safely do
2, 3, 14, 15Grid OvervoltageGrid voltage at your home went above the inverter’s limit, so it stopped exporting.Wait. If it repeats most sunny afternoons, tell your installer.
4, 5Grid UndervoltageGrid voltage fell below the limit.Wait. If it repeats, call your installer.
8, 9Grid Overfrequency / UnderfrequencyGrid frequency went outside the set range.Wait. If it repeats, call your installer.
10Grid Power OutageThe inverter can’t see the grid: a blackout, or its AC supply is off.Check whether the house and street have power. If the house does and the inverter still shows 10, call your installer.
13Grid AbnormalAnother grid reading is out of range.Wait. If it repeats, call your installer.
17Grid Voltage ImbalanceThe phases differ too much (three-phase homes).Wait. If it repeats, call your installer.
12Excess Leakage CurrentToo much current leaking to earth. The manual names poor sunlight or a damp environment as causes.Wait for things to dry. If it happens in dry weather, call an electrician.
39Low System Insulation ResistanceThe insulation between the solar wiring and earth is too low (the “ISO” fault).Wait. If it keeps coming back, call an electrician to test the strings.
106Grounding Cable FaultA problem with the earth connection on the AC side.Don’t touch anything. Call your installer.
88Electric Arc FaultArcing detected in the solar (DC) wiring.Don’t clear it yourself. The manual’s fix is inspecting DC cables and terminals: electrician only.
37Excessively High Ambient TemperatureToo hot in or around the inverter.Wait: it restarts as it cools. Make sure nothing is stacked against it.
43Excessively Low Ambient TemperatureToo cold to run.The manual says restart once it warms into range. Ask your installer if it repeats.
51Off-Grid Load OverPower Fault (hybrids)Too much running on the backup circuit during an outage.Switch off big loads on backup, such as heaters or an oven.
84Reverse Connection Alarm of the Meter/CTThe meter or its current sensor is wired the wrong way round.Call your installer. Your usage and export figures will be wrong until it is fixed.
514Meter Communication Abnormal AlarmThe inverter has lost contact with its smart meter.Call your installer.
714BMS Communication FaultThe inverter has lost contact with the battery’s management system.Call your installer. The manual’s checks are on the communication cable.
716Abnormal Battery ConnectionThe battery reads as reversed or not connected.Call your installer.
703, 711, 712, 715, 717Battery FaultA battery fault the SBR manual says generally clears by itself within 20 minutes.Wait 20 minutes. If it keeps happening, call your installer.
707, 733 / 708, 734Battery Fault (temperature)Battery too hot / too cold for its operating range.Check nothing is heating the battery. If it persists, call your installer.
932–935, 937, 939–943, 964Battery AlarmA battery warning that generally recovers by itself.Wait. If it lasts, call your installer.
1600–1615, 1632–1655PV Grounding FaultA solar string has an earth fault.Leave the DC switch alone. Call your installer.
1616System Hardware FaultAn internal hardware fault.The manual says don’t power the inverter up again. Call your installer.
Long list (7, 11, 16, 19–25 and more)System FaultA general internal fault.Wait. If it doesn’t clear, use the restart below once. If it returns, call.
Long list (59, 70–74 and more)System AlarmA warning. The manual says the inverter can keep running.Note it and mention it to your installer.

Why does a Sungrow show a grid fault
after a storm or on a sunny afternoon?

Because the grid moved, not because the inverter broke.

What do codes 12, 39 and 106 mean
on a damp morning?

Water and solar wiring, and when it stops being weather.

⚠
Never open the inverter or touch the solar wiring. The solar panels and their cables stay live in daylight even with every switch off. Sungrow’s manual also forbids opening the inverter if there is a smell, smoke or visible damage. If you see any of those, switch off the AC supply to the inverter at your switchboard only if it is safe to reach, keep away, and call a licensed electrician.

Why does a Sungrow cut out
on hot afternoons?

Code 37, and the derating that comes before it.

What do Sungrow battery codes mean
on an SBR or SH hybrid?

The 700s to 900s, and the one battery rule you must not miss.

How do I safely restart
a Sungrow inverter?

Once, in Sungrow’s order, and only for the right codes.

Is a Sungrow fault
covered by warranty?

Sungrow Australia’s terms, and who you call first.

When should you stop
and call an electrician?

Any one of these is enough.

Sungrow fault codes:
your questions, answered.

Code 10 is Grid Power Outage: the inverter can't see the grid, usually because of a blackout, so it stops feeding power into the lines. Sungrow's manuals (SG-RS Ver24, June 2025; SH-RT Ver24, March 2025, which writes it as 010) say it generally reconnects by itself once the grid returns to normal. If your house has power and the inverter still shows 10, its AC supply may be off or tripped. Call your installer rather than resetting a tripped breaker.

Code 39 is Low System Insulation Resistance, often called an ISO fault: the insulation between the solar wiring and earth has measured too low. Sungrow's SG2.0–6.0RS manual (Ver24, June 2025) says to wait for the inverter to recover, and if it happens on rainy days, check again when the weather turns fine. If it returns every wet morning or appears in dry weather, an electrician needs to test the strings and cables. Never touch the solar wiring yourself.

Code 37 is Excessively High Ambient Temperature. The inverter has got too hot and stops until it cools; Sungrow's manual says it generally resumes once the temperature returns to normal. The SG-RS and SH-RS models are rated to run from −25 °C to 60 °C and cut their output before tripping. If 37 repeats every summer, ask your installer about shade and ventilation: Sungrow's October 2025 warranty excludes damage caused by insufficient ventilation.

Only once, and not for codes 88, 106, the 1600s or 1616, or if there is smoke or a burning smell. Sungrow's 2025 manuals give the order: turn off the inverter's AC circuit breaker, turn the inverter's DC switch off, switch off the battery if fitted, and wait 15 minutes. Then turn the AC breaker on first, the battery next, and the DC switch last. If the red light returns, stop and call your installer.

Code 714 is BMS Communication Fault: the hybrid inverter has lost contact with the battery's management system. Sungrow's SH3.0–6.0RS manual (Ver20, March 2025) and SBR battery manual (Ver22, February 2025) both point to the communication cable between inverter and battery, which is installer work. If the battery's charge falls below 3% while a fault is active, the SBR manual says to switch the battery off to prevent over-discharge damage.

Usually, if it is a defect. Sungrow Australia's inverter warranty (V4.31, October 2025) covers listed residential models, including the SG-RS and SH-RS ranges, for 10 years from installation but no more than 11 years from manufacture. You start with your installer, who troubleshoots and contacts Sungrow, and the claim needs proof of purchase. Faulty installation, unauthorised repairs, insufficient ventilation, lightning and grid surges are excluded.

They are the same code. Sungrow's three-phase SH5.0–10RT manual (Ver24, March 2025) writes alarm IDs with leading zeros, such as 002 for Grid Overvoltage and 010 for Grid Power Outage, while the single-phase SG-RS and SH-RS manuals write 2 and 10. Codes 2, 3, 14 and 15 are all grid overvoltage, and the manuals say the inverter generally reconnects by itself once the grid returns to normal.

Where these
figures come from.

Every code, name and step above comes from Sungrow’s own documents, downloaded from Sungrow’s sites and read 9 November 2026. The plain-English summaries are ours. This is general information: your installer and your model’s manual come first.

Keep reading

Related honest guides.

Inverter red light?

Every brand’s light table, the one safe reset, and when to call.

Read the guide →

Is my solar working?

Four checks from the driveway, and the failures that never trigger a light.

Read the guide →

Solar stopped exporting?

Inverter faults, meters, export limits and grid voltage, in order.

Read the guide →

Sungrow SBR vs SBH

How Sungrow’s two battery ranges differ, and what each backs up.

Read the guide →

Repair or replace?

How long inverters last, the signs, and the 8-year repair rule.

Read the guide →

Installer gone?

The warranty claim ladder when the company that installed it has closed.

Read the guide →

Same Sungrow code every week?

Send us the code and when it happens. We’ll tell you honestly whether it’s the grid, the weather or the hardware, and whether it needs anyone at all.

Get a free quote →