Sungrow inverter fault codes: what each one means, and what to do
As at November 2026, Sungrow’s manuals sort the codes into families: 2 to 10 are grid faults, 12 and 39 flag damp or insulation problems, 37 is heat, and the 700s to 900s are battery faults. Most red lights after a storm or on a hot afternoon are grid or temperature faults that clear themselves. Here is how to tell.
Written by Juan Flinn, Content Editor · Reviewed by the Mission Green Energy Team · Updated 9 November 2026
What does a Sungrow code
actually tell you?
Which family it is in, and whether the inverter expects to fix itself.
A Sungrow inverter with a fault shows a steady red light. On the single-phase SG-RS string and SH-RS hybrid models, touching the light shows the code on the small screen, which goes dark after five minutes without a touch. The three-phase RT models have no code screen, so you read the code in the iSolarCloud app. The RT manual writes codes with leading zeros (002, 010); the RS manuals write 2 and 10. They are the same codes.
Sungrow’s own instruction for most grid codes starts the same way: generally, the inverter reconnects once the grid returns to normal. So the first job is to wait and see if it clears. What each light means, brand by brand, is on our inverter red light guide. This page goes deeper on the numbers. Other brands: GoodWe error codes and Fronius state codes.
2–17 · 37
Grid voltage, frequency or outage, and heat. Wait, then watch whether it repeats.
12 · 39
Leakage current and low insulation resistance. One wet morning is weather; every wet morning is a fault.
88 · 106 · 1600s · 1616
Arc fault, grounding faults and a hardware fault. Leave the switches and call your installer.
Which Sungrow code
is on your screen?
Codes and names from Sungrow’s SG2.0–6.0RS manual (Ver24, June 2025), SH3.0–6.0RS hybrid manual (Ver20, March 2025), SH5.0–10RT manual (Ver24, March 2025) and SBR battery manual (Ver22, February 2025). The wording is our summary, not the manual’s.
| Code | Manual’s name | What it means | What you can safely do |
|---|---|---|---|
| 2, 3, 14, 15 | Grid Overvoltage | Grid voltage at your home went above the inverter’s limit, so it stopped exporting. | Wait. If it repeats most sunny afternoons, tell your installer. |
| 4, 5 | Grid Undervoltage | Grid voltage fell below the limit. | Wait. If it repeats, call your installer. |
| 8, 9 | Grid Overfrequency / Underfrequency | Grid frequency went outside the set range. | Wait. If it repeats, call your installer. |
| 10 | Grid Power Outage | The inverter can’t see the grid: a blackout, or its AC supply is off. | Check whether the house and street have power. If the house does and the inverter still shows 10, call your installer. |
| 13 | Grid Abnormal | Another grid reading is out of range. | Wait. If it repeats, call your installer. |
| 17 | Grid Voltage Imbalance | The phases differ too much (three-phase homes). | Wait. If it repeats, call your installer. |
| 12 | Excess Leakage Current | Too much current leaking to earth. The manual names poor sunlight or a damp environment as causes. | Wait for things to dry. If it happens in dry weather, call an electrician. |
| 39 | Low System Insulation Resistance | The insulation between the solar wiring and earth is too low (the “ISO” fault). | Wait. If it keeps coming back, call an electrician to test the strings. |
| 106 | Grounding Cable Fault | A problem with the earth connection on the AC side. | Don’t touch anything. Call your installer. |
| 88 | Electric Arc Fault | Arcing detected in the solar (DC) wiring. | Don’t clear it yourself. The manual’s fix is inspecting DC cables and terminals: electrician only. |
| 37 | Excessively High Ambient Temperature | Too hot in or around the inverter. | Wait: it restarts as it cools. Make sure nothing is stacked against it. |
| 43 | Excessively Low Ambient Temperature | Too cold to run. | The manual says restart once it warms into range. Ask your installer if it repeats. |
| 51 | Off-Grid Load OverPower Fault (hybrids) | Too much running on the backup circuit during an outage. | Switch off big loads on backup, such as heaters or an oven. |
| 84 | Reverse Connection Alarm of the Meter/CT | The meter or its current sensor is wired the wrong way round. | Call your installer. Your usage and export figures will be wrong until it is fixed. |
| 514 | Meter Communication Abnormal Alarm | The inverter has lost contact with its smart meter. | Call your installer. |
| 714 | BMS Communication Fault | The inverter has lost contact with the battery’s management system. | Call your installer. The manual’s checks are on the communication cable. |
| 716 | Abnormal Battery Connection | The battery reads as reversed or not connected. | Call your installer. |
| 703, 711, 712, 715, 717 | Battery Fault | A battery fault the SBR manual says generally clears by itself within 20 minutes. | Wait 20 minutes. If it keeps happening, call your installer. |
| 707, 733 / 708, 734 | Battery Fault (temperature) | Battery too hot / too cold for its operating range. | Check nothing is heating the battery. If it persists, call your installer. |
| 932–935, 937, 939–943, 964 | Battery Alarm | A battery warning that generally recovers by itself. | Wait. If it lasts, call your installer. |
| 1600–1615, 1632–1655 | PV Grounding Fault | A solar string has an earth fault. | Leave the DC switch alone. Call your installer. |
| 1616 | System Hardware Fault | An internal hardware fault. | The manual says don’t power the inverter up again. Call your installer. |
| Long list (7, 11, 16, 19–25 and more) | System Fault | A general internal fault. | Wait. If it doesn’t clear, use the restart below once. If it returns, call. |
| Long list (59, 70–74 and more) | System Alarm | A warning. The manual says the inverter can keep running. | Note it and mention it to your installer. |
The manuals say only some of these codes can occur on any one model. If your code isn’t here, it isn’t one we could confirm in Sungrow’s current residential manuals, so write it down exactly and ask your installer rather than guessing from a forum.
Why does a Sungrow show a grid fault
after a storm or on a sunny afternoon?
Because the grid moved, not because the inverter broke.
After a storm, the usual codes are 10 (Grid Power Outage) and 4 or 5 (Grid Undervoltage). The inverter has anti-islanding protection, listed in the manual’s safety functions, so it must stop feeding power into lines that are down. When the grid is back and steady, it reconnects on its own. If your street has power and the inverter still shows 10 an hour later, the inverter’s own AC supply may be off. If you didn’t turn it off, don’t just flick it back on: a breaker that trips has a reason, so call your installer.
On a sunny afternoon, the usual codes are 2, 3, 14 or 15 (Grid Overvoltage). When a whole street exports at once, local voltage climbs, and an inverter must stop when it passes its limit. The SH-RS manual also lists grid over-voltage and over-temperature among the reasons it cuts its own output (derating) before it trips altogether.
If it happens most sunny afternoons, the manual’s steps are to measure the grid voltage and contact the network, and to change protection settings only with the network’s consent. That is a job for your installer, not a setting to nudge in the app. Our guide to solar that has stopped exporting covers the voltage problem in more detail.
What do codes 12, 39 and 106 mean
on a damp morning?
Water and solar wiring, and when it stops being weather.
Code 12 (Excess Leakage Current) and code 39 (Low System Insulation Resistance) both mean the inverter has measured a path to earth that shouldn’t be there. Sungrow’s manual says code 12 can be caused by poor sunlight or a damp environment, and that the inverter reconnects once conditions improve. For code 39 it says that if the cabling is normal and the fault occurs on rainy days, check again when the weather turns fine.
So one fault on a foggy morning that clears by ten o’clock is not an emergency. A fault that appears every wet morning, or in dry weather, is different: water is getting into a connector or a damaged cable somewhere, and it will get worse. The manual’s next step is measuring the resistance to earth of each string and cable, which needs an electrician with test gear on the roof.
Code 106 (Grounding Cable Fault) and the earth-fault alarm are not weather. The manual says that if the AC side is poorly grounded or not grounded, the buzzer rings and the light turns red. The 1600s (PV Grounding Fault) carry a specific warning: the manual forbids turning off the DC switch while more than 0.5 A is flowing, which an owner can’t measure. Leave the DC switch alone and call your installer.
Why does a Sungrow cut out
on hot afternoons?
Code 37, and the derating that comes before it.
Code 37 (Excessively High Ambient Temperature) means the inverter is too hot to keep running. The manual says it generally resumes once the internal or module temperature returns to normal. Before it gets that far, the inverter derates: it cuts its own output to protect itself, so you may see lower generation on a hot afternoon with no code at all. The SG-RS and SH-RS specification sheets give an operating range of −25 °C to +60 °C.
The manual’s checks for a repeating 37 are the ambient temperature, ventilation, direct sun on the inverter and whether the fan is working. The one you can do is make sure nothing is stacked against it or covering it: the routine maintenance table says nothing should cover the heat sink. Shading, moving or replacing a fan is installer work.
It is worth fixing for another reason. Sungrow’s Australian warranty excludes damage caused by insufficient ventilation. If your inverter sits in afternoon sun in a cramped spot and throws 37 every summer, raise it with your installer now rather than at claim time.
What do Sungrow battery codes mean
on an SBR or SH hybrid?
The 700s to 900s, and the one battery rule you must not miss.
Battery faults show up through the hybrid inverter and the iSolarCloud app. The SBR battery’s own status light is blue when normal (slow blink at power-on, standby or a firmware update; fast blink during its self-test) and red for a fault: steady red is a system fault, blinking red is a fault at power-on or standby. Each bar on its charge display is 10%.
714 means the inverter has lost touch with the battery’s management system; the manual’s checks are on the communication cable, so that is your installer. The 703, 711, 712, 715 and 717 group, the SBR manual says, generally clears by itself within 20 minutes. 707 and 733 mean too hot and 708 and 734 too cold: the SBR charges between 0 and 55 °C and discharges between −20 and 55 °C. The 932, 939 and 964 alarms generally recover by themselves.
The rule that matters: for every battery fault, the SBR manual says to switch the battery off immediately if its charge drops below 3%, to avoid damage from over-discharge. Switching it off means its own DC circuit breaker, which your installer should have shown you at handover. If a battery has been in floodwater, the manual says switch off all the circuit breakers in the system, stay away, and never use it again.
We used the SBR manual. The newer SBH has its own manual, which we didn’t use here; our SBR vs SBH comparison covers how the two differ. If the battery isn’t faulting but behaves oddly, see why a battery charges from the grid.
How do I safely restart
a Sungrow inverter?
Once, in Sungrow’s order, and only for the right codes.
Don’t restart if there is a smell, smoke, scorching or visible damage, or for codes 88, 106, the 1600s or 1616. For a System Fault that won’t clear, the manual’s step is: switch off the AC and DC (and the battery, if you have one), wait 15 minutes, then switch back on. Sungrow’s shutdown and power-on sections give the order:
- Turn off the AC circuit breaker that feeds the inverter. It is usually labelled as the solar or inverter main switch at your switchboard.
- Turn the DC switch on the inverter to OFF.
- If you have a battery, switch off the battery’s circuit breaker.
- Wait 15 minutes. The manual says the inside needs about 10 minutes to discharge; the System Fault step says 15.
- Turn the AC circuit breaker back on first.
- Switch the battery back on, if you have one, the way your installer showed you.
- Turn the DC switch on the inverter to ON last.
A flashing blue light means it is starting up; steady blue means it is running. Sungrow says to follow the power-on order strictly, and that damage from doing otherwise isn’t covered by warranty. Note this is AC on first, which is not the order every brand uses. If the red light comes back, stop resetting and call. A light that is off doesn’t mean the inverter is safe to touch: the manual warns that voltage may still be present on the AC side.
Is a Sungrow fault
covered by warranty?
Sungrow Australia’s terms, and who you call first.
Sungrow Australia’s inverter warranty (version 4.31, October 2025) covers the listed residential models, including the SG-RS and SH-RS single-phase ranges and the RT three-phase models it names, for 10 years from installation, but no more than 11 years from manufacture. Accessories such as the Wi-Fi dongle and smart meter get 1 year from installation, no more than 2 from manufacture. SBR and SBH batteries have a separate warranty: 10 years from installation or 126 months from manufacture, whichever comes first.
The claim process starts with your installer, who does the first troubleshooting and contacts Sungrow if needed. Claims are lodged online with proof of purchase or the commissioning report. The exclusions that matter for faults: not following the manual, unauthorised repairs, insufficient ventilation, lightning, and surges coming from the grid or the panels. If your installer has gone out of business, see how to claim when the installer is gone.
When should you stop
and call an electrician?
Any one of these is enough.
- Any smell of burning, smoke, scorch marks, melted plastic, or a buzzing switch.
- Code 88, 106, any 1600s code, 1616, or the earth-fault buzzer.
- Code 12 or 39 on dry days, or every time it rains.
- The same grid code most sunny afternoons, or code 10 while the house has power.
- A System Fault that returns after one restart.
- A battery fault with the charge falling towards 3%.
Before you call, photograph the screen or app with the code, and note the time, the weather and whether it cleared. Not sure the system is working at all? Our sixty-second solar check helps. If the same faults keep coming on an older unit, read when an inverter needs replacing. More on the brand itself is on our Sungrow page.
Sungrow fault codes:
your questions, answered.
Code 10 is Grid Power Outage: the inverter can't see the grid, usually because of a blackout, so it stops feeding power into the lines. Sungrow's manuals (SG-RS Ver24, June 2025; SH-RT Ver24, March 2025, which writes it as 010) say it generally reconnects by itself once the grid returns to normal. If your house has power and the inverter still shows 10, its AC supply may be off or tripped. Call your installer rather than resetting a tripped breaker.
Code 39 is Low System Insulation Resistance, often called an ISO fault: the insulation between the solar wiring and earth has measured too low. Sungrow's SG2.0–6.0RS manual (Ver24, June 2025) says to wait for the inverter to recover, and if it happens on rainy days, check again when the weather turns fine. If it returns every wet morning or appears in dry weather, an electrician needs to test the strings and cables. Never touch the solar wiring yourself.
Code 37 is Excessively High Ambient Temperature. The inverter has got too hot and stops until it cools; Sungrow's manual says it generally resumes once the temperature returns to normal. The SG-RS and SH-RS models are rated to run from −25 °C to 60 °C and cut their output before tripping. If 37 repeats every summer, ask your installer about shade and ventilation: Sungrow's October 2025 warranty excludes damage caused by insufficient ventilation.
Only once, and not for codes 88, 106, the 1600s or 1616, or if there is smoke or a burning smell. Sungrow's 2025 manuals give the order: turn off the inverter's AC circuit breaker, turn the inverter's DC switch off, switch off the battery if fitted, and wait 15 minutes. Then turn the AC breaker on first, the battery next, and the DC switch last. If the red light returns, stop and call your installer.
Code 714 is BMS Communication Fault: the hybrid inverter has lost contact with the battery's management system. Sungrow's SH3.0–6.0RS manual (Ver20, March 2025) and SBR battery manual (Ver22, February 2025) both point to the communication cable between inverter and battery, which is installer work. If the battery's charge falls below 3% while a fault is active, the SBR manual says to switch the battery off to prevent over-discharge damage.
Usually, if it is a defect. Sungrow Australia's inverter warranty (V4.31, October 2025) covers listed residential models, including the SG-RS and SH-RS ranges, for 10 years from installation but no more than 11 years from manufacture. You start with your installer, who troubleshoots and contacts Sungrow, and the claim needs proof of purchase. Faulty installation, unauthorised repairs, insufficient ventilation, lightning and grid surges are excluded.
They are the same code. Sungrow's three-phase SH5.0–10RT manual (Ver24, March 2025) writes alarm IDs with leading zeros, such as 002 for Grid Overvoltage and 010 for Grid Power Outage, while the single-phase SG-RS and SH-RS manuals write 2 and 10. Codes 2, 3, 14 and 15 are all grid overvoltage, and the manuals say the inverter generally reconnects by itself once the grid returns to normal.
Where these
figures come from.
Every code, name and step above comes from Sungrow’s own documents, downloaded from Sungrow’s sites and read 9 November 2026. The plain-English summaries are ours. This is general information: your installer and your model’s manual come first.
- Sungrow — SG2.0–6.0RS user manual, Ver24, June 2025 (LED panel, disconnecting, troubleshooting)
- Sungrow — SH3.0–6.0RS hybrid user manual, Ver20, March 2025 (earth-fault alarm, derating, power-on order, alarm IDs)
- Sungrow — SH5.0–10RT hybrid user manual, Ver24, March 2025 (three-digit alarm IDs)
- Sungrow — SBR064–256 battery user manual, Ver22, February 2025 (status light, battery fault codes)
- Sungrow Australia — Inverters 10-Year Limited Warranty, V4.31, October 2025
- Sungrow Australia — HV Battery Limited Warranty, V8.0, October 2024